Supportek provides quality solutions for UPS needs that can be measured in lower energy and operating costs, while maintaining reliability within your critical power infrastructure. When reliability and peace of mind are critical to your operation, give us a call so that we can assess your needs.

ONLINE THREE-PHASE


Three-Phase UPS systems operating in the online double conversion mode offer you the best in reliable protection by isolating your loads from incoming utility power problems (Power failures, Power Sags, Power Spikes/Surges, Undervoltages (brownouts), Overvoltages, Electrical Line Noise, Frequency Variations, Switching Transients, and Harmonic Distortion. In the worst case scenario of a power outage there is a zero transfer time from the UPS’s rectifier operation that supports the inverter to the batteries.

ACTIVE POWER

ative-power-ups

Active Power offers three phase uninterruptible power supply (UPS) that enable data centers and other mission critical applications to remain ‘on’ 24 hours a day, seven days a week. Its CleanSource® UPS product line, designed in 300 kVA building blocks, can be configured up to 1.5 MVA with the ability to parallel systems for more than 8 MW of load protection. Rated at 750 kVA, the company’s CleanSource® High Density UPS product line can be paralleled for more than 5 MVA of load protection.

For a complete modular power solution, PowerHouse™ is ideal for facility expansion or to replace a conventional electrical room as it integrates all critical physical infrastructure components into a purpose built enclosure. Rated at 240 kW to 960 kW, the system lowers electrical infrastructure capital expenses by as much as 25 percent, reduces total time to deployment from more than a year to less than 30 weeks versus a conventional build, and provides superior real time analytics and systems control.

ISOLATED ONLINE


Isolated Online UPS, also known as Power Conditioned Online UPS or Laboratory Grade UPS, protect against all 10 of the common power problems. This premium technology adds galvanic isolation transformer to the online UPS topology providing protection from common mode noise. Isolated Online UPS are used to provide the cleanest power in difficult applications such as industrial environments, laboratories, retail, and any installation with grounding or noise issues.

ONLINE SINGLE-PHASE


Single-Phase UPS systems operating in the online double conversion mode offer you the best in reliable protection by isolating your loads from incoming utility power problems(Power failures, Power Sags, Power Spikes/Surges, Undervoltages (brownouts), Overvoltages, Electrical Line Noise, Frequency Variations, Switching Transients and Harmonic Distortion. In the worst case scenario of a power outage there is a zero transfer time from the UPS’s rectifier operation that supports the inverter to the batteries.

LINE INTERACTIVE


Line-Interactive UPS systems are used in many cases in network closets and on some servers. These units will protect your loads against Power failures, Power Sags, Power Spikes/Surges, Undervoltages (brownouts) and Overvoltages. Line-interactive UPS’s utilize a buck and boost topology in order to maintain the output voltage during power surges and sags and when power drops too low, goes too high our simply is lost then the unit transfers to the inverter in 2-4 milliseconds.

STANDBY


Standby UPS systems are used in for home computers, A/V equipment or simple workstations. These units will protect your loads against Power failures, Power Sags, and Power Spikes/Surges. Standby UPS’s are the simplest of the UPS topologies. Utility power always supports your loads until the utility power goes outside of the UPS input parameters and then the unit transfers to the inverter in 2-4 milliseconds.